A preliminary analysis of subfloor ventilation data: bridging the gap between theory and experiment

journal contribution
posted on 2023-05-17, 03:05 authored by Sabrina SequeiraSabrina Sequeira, Mark FayMark Fay, Jane SargisonJane Sargison, Soriano, FP
AccuRate, the building performance simulation program developed by Australia's Commonwealth Scientific and Industrial Research Organisation, consists of a set of physics-based models. Recent research seeking to validate the AccuRate program using experimental data suggests that the subfloor model may be inaccurate. This study experimentally investigates the ventilation component of that subfloor model. In this article, the University of Tasmania's thermal performance test site is analysed to show that its centre test cell is suitable for ventilation testing. Subfloor ventilation data are then shown to generally match AccuRate's theoretical prediction. The data are further explored to find nuances resulting from obstructions from surrounding buildings. The data are also benchmarked against subfloor ventilation studies from Australia and the UK. Although this study does not purport to fully validate the AccuRate subfloor model, it does greatly contribute to the amount of published experimental subfloor ventilation data from an Australian building and climate.

History

Publication title

Architectural Science Review

Volume

53

Pagination

315-322

ISSN

1758-9622

Department/School

School of Engineering

Publisher

Earthscan

Place of publication

London, UK

Rights statement

Copyright 2010 Earthscan

Repository Status

  • Restricted

Socio-economic Objectives

Residential construction design