Left atrial booster pump function is an independent predictor of subsequent life-threatening ventricular arrhythmias in non-ischaemic cardiomyopathy

journal contribution
posted on 2023-05-18, 15:28 authored by Kazuaki Negishi, Tomoko Negishi, Zardkoohi, O, Ching, EA, Basu, N, Wilkoff, BL, Popovic, ZB, Thomas MarwickThomas Marwick

Aims: Left atrial (LA) function helps to preserve cardiac output and to control pulmonary capillary wedge pressure in the setting of left ventricular (LV) impairment, but little is known about the contribution of the LA function to ventricular arrhythmia. We sought whether LA booster pump function was associated with arrhythmias in patients undergoing primary prevention implantable cardioverter-defibrillator (ICD) implantation for non-ischaemic dilated cardiomyopathy (NICM), independent of global longitudinal strain (GLS) and mechanical dispersion (MD).

Methods and results: We identified 124 NICM patients (56 ± 13, 67 male) who underwent echocardiography pre-ICD implantation for primary prevention. The main outcome measure was appropriate ICD therapy (anti-tachycardia pacing or shock). The mitral A-wave was used as an LA functional marker. MD was defined as standard deviation of time to peak strain of each segment. Over a median follow-up of 3.8 ± 2.2 years, 36 patients had appropriate ICD therapy, including 23 shocks. Patients with appropriate ICD therapy had lower A-wave velocity (P < 0.001), larger LA volume (P < 0.001), and impaired circumferential MD (P = 0.006), but similar ejection fraction (EF) (P = 0.40) and GLS (P = 0.11). In sequential Cox proportional hazards models, A-wave, E/A ratio, and GLS were significantly associated with outcomes, independent of age, sex, and cardiac resynchronization therapy defibrillator or left bundle branch block. In nested Cox models, mitral A-wave had a prognostic value incremental to models with LV systolic (EF and GLS) and diastolic functional parameters (E/A, E/e′, and LA volume) and MD.

Conclusion: LA booster pump function was an independent and incremental predictor of arrhythmias in NICM over GLS and MD, and may aid better risk stratification in this population.

History

Publication title

European Heart Journal Cardiovascular Imaging

Volume

17

Pagination

1153-1160

ISSN

2047-2412

Department/School

Menzies Institute for Medical Research

Publisher

Oxford University Press

Place of publication

United Kingdom

Rights statement

Copyright 2015 The Authors

Repository Status

  • Restricted

Socio-economic Objectives

Clinical health not elsewhere classified

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC