Transient isotachophoresis-capillary zone electrophoresis with contactless conductivity and ultraviolet detection for the analysis of paralytic shellfish toxins in mussel samples

Citation

Abdul Keyon, AS and Guijt, RM and Bolch, CJS and Breadmore, MC, Transient isotachophoresis-capillary zone electrophoresis with contactless conductivity and ultraviolet detection for the analysis of paralytic shellfish toxins in mussel samples, Journal of Chromatography A, 1364 pp. 295-302. ISSN 0021-9673 (2014) [Refereed Article]

Copyright Statement

Copyright 2014 Elsevier

DOI: doi:10.1016/j.chroma.2014.08.074

Abstract

The accumulation of paralytic shellfish toxins (PSTs) in contaminated shellfish is a serious health risk making early detection important to improve shellfish safety and biotoxin management. Capillary electrophoresis (CE) has been proven as a high resolution separation technique compatible with miniaturization, making it an attractive choice in the development of portable instrumentation for early,on-site detection of PSTs. In this work, capillary zone electrophoresis (CZE) with capacitively coupled contactless conductivity detector (C4D) and UV detection were examined with counter-flow transient isotachophoresis (tITP) to improve the sensitivity and deal with the high conductivity sample matrix. The high sodium concentration in the sample was used as the leading ion while l-alanine was used as the terminating electrolyte (TE) and background electrolyte (BGE) in which the toxins were separated. Careful optimization of the injected sample volume and duration of the counter-flow resulted in limit of detections (LODs) ranging from 74.2 to 1020 ng/mL for tITP-CZE-C4D and 141 to 461 ng/mL for tITP-CZE-UV, an897 fold reduction compared to conventional CZE. The LODs were adequate for the analysis of PSTs in shellfish samples close to the regulatory limit. Intra-day and inter-day repeatability values (percentage relative standard deviation, n = 3) of tITP-CZE-C4D and tITP-CZE-UV methods for both migration time and peak height were in the range of 0.8211% and 0.7610%, respectively. The developed method was applied to the analysis of a contaminated mussel sample and validated against an Association of Official Analytical Chemists (AOAC)-approved method for PSTs analysis by high performance liquid chromatography (HPLC) with fluorescence detection (FLD) after pre-column oxidation of the sample. The method presented has potential for incorporation in to field-deployable devices for the early detection of PSTs on-site.

Item Details

Item Type:Refereed Article
Keywords:transient isotachophoresis, capillary zone electrophoresis, contactless conductivity, paralytic shellfish toxins
Research Division:Chemical Sciences
Research Group:Analytical Chemistry
Research Field:Separation Science
Objective Division:Animal Production and Animal Primary Products
Objective Group:Fisheries - Aquaculture
Objective Field:Fisheries - Aquaculture not elsewhere classified
Author:Abdul Keyon, AS (Mrs Aemi Abdul Keyon)
Author:Guijt, RM (Dr Rosanne Guijt)
Author:Bolch, CJS (Dr Christopher Bolch)
Author:Breadmore, MC (Professor Michael Breadmore)
ID Code:95168
Year Published:2014
Web of Science® Times Cited:7
Deposited By:NC Marine Conservation and Resource Sustainability
Deposited On:2014-09-25
Last Modified:2015-03-17
Downloads:0

Repository Staff Only: item control page