eCite Digital Repository

Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise

Citation

Sharman, JE and Lim, R and Qasem, AM and Coombes, JS and Burgess, MI and Franco, J and Garrahy, P and Wilkinson, IB and Marwick, TH, Validation of a generalized transfer function to noninvasively derive central blood pressure during exercise, Hypertension, 47, (6) pp. 1203-1208. ISSN 0194-911X (2006) [Refereed Article]

DOI: doi:10.1161/01.HYP.0000223013.60612.72

Abstract

Exercise brachial blood pressure (BP) predicts mortality, but because of wave reflection, central (ascending aortic) pressure differs from brachial pressure. Exercise central BP may be clinically important, and a noninvasive means to derive it would be useful. The purpose of this study was to test the validity of a noninvasive technique to derive exercise central BP. Ascending aortic pressure waveforms were recorded using a micromanometer-tipped 6F Millar catheter in 30 patients (56±9 years; 21 men) undergoing diagnostic coronary angiography. Simultaneous recordings of the derived central pressure waveform were acquired using servocontrolled radial tonometry at rest and during supine cycling. Pulse wave analysis of the direct and derived pressure signals was performed offline (SphygmoCor 7.01). From rest to exercise, mean arterial pressure and heart rate were increased by 20±10 mm Hg and 15±7 bpm, respectively, and central systolic BP ranged from 77 to 229 mm Hg. There was good agreement and high correlation between invasive and noninvasive techniques with a mean difference (±SD) for central systolic BP of -1.3±3.2 mm Hg at rest and -4.7±3.3 mm Hg at peak exercise (for both r=0.995; P<0.001). Conversely, systolic BP was significantly higher peripherally than centrally at rest (155±33 versus 138±32 mm Hg; mean difference, -16.3±9.4 mm Hg) and during exercise (180±34 versus 164±33 mm Hg; mean difference, -15.5±10.4 mm Hg; for both P<0.001). True myocardial afterload is not reliably estimated by peripheral systolic BP. Radial tonometry and pulse wave analysis is an accurate technique for the noninvasive determination of central BP at rest and during exercise.

Item Details

Item Type:Refereed Article
Research Division:Medical and Health Sciences
Research Group:Cardiorespiratory Medicine and Haematology
Research Field:Cardiology (incl. Cardiovascular Diseases)
Objective Division:Health
Objective Group:Clinical Health (Organs, Diseases and Abnormal Conditions)
Objective Field:Cardiovascular System and Diseases
Author:Sharman, JE (Professor James Sharman)
ID Code:61295
Year Published:2006
Web of Science® Times Cited:203
Deposited By:Menzies Institute for Medical Research
Deposited On:2010-03-02
Last Modified:2010-05-03
Downloads:0

Repository Staff Only: item control page