posted on 2023-05-16, 19:58 authored by Penner, NA, Nesterenko, PN, Rybalko, MAAdsorption isotherms of pyrocatechol, resorcinol, and hydroquinone on hypercrosslinked polystyrene MN-200 are described by the Langmuir equation; distribution coefficients of these compounds are 1500, 550, and 370 mL/g, respectively; breakthrough capacities are 15.3, 11.2, and 11.3 mg/g, respectively. The comparison of hypercrosslinked polystyrene with other sorbents in the efficiency of the dynamic preconcentration of hydroxyphenols demonstrated its advantages. A procedure is proposed for the determination of pyrocatechol, resorcinol, and hydroquinone in water by high-performance liquid chromatography with dynamic on-line preconcentration on a concentrating column instead of the injector loop, which provides the determination of these compounds at concentrations down to 2-3 μg/L. The accuracy of the procedure was verified by the added-found method with a water sample. © 2001 MAIK "Nauka/Interperiodica".
History
Publication title
Journal of Analytical ChemistryVolume
56Issue
10Pagination
934-939ISSN
1061-9348Department/School
School of Natural SciencesPublisher
MAIK Nauka - InterperiodicaPlace of publication
Russian FederationRepository Status
- Restricted