University of Tasmania
Browse
1/1
2 files

Temperature Profiles and Heat Dissipation in Capillary Electrophoresis

journal contribution
posted on 2023-05-16, 18:46 authored by Evenhuis, CJ, Rosanne Guijt, Miroslav MackaMiroslav Macka, Marriott, PJ, Paul HaddadPaul Haddad
While temperature control is usually employed in capillary electrophoresis (CE) to aid heat dissipation and provide acceptable precision, internal electrolyte temperatures are almost never measured. In principle, this limits the accuracy, repeatability, and method robustness. This work presents a fundamental study that combines the development of new equations characterizing temperature profiles in CE with a new method of temperature determination. New equations were derived from first principles relating the mean, axial, and inner wall electrolyte temperatures (TMean, TAxis, T Wall). TMean was shown to occur at a distance 1/√3 times the internal radius of the capillary from the center of the capillary and to be a weighted average of 2/3TAxis and 1/3TWall. Conductance (G) and electroosmotic mobility (μEOF) can be used to determine TMean and TWall, respectively. Extrapolation of curves of μEOF versus power per unit length (P/L) at different temperatures was used to calibrate the variation of μEOF with temperature (T), free from Joule heating effects. μEOF increased at 2.22%/°C. The experimentally determined temperatures using μEOF agreed to within 0.2°C with those determined using G. The accuracy of G measurements was confirmed independently by measuring the electrical conductivity (κ) of the bulk electrolyte over a range of temperatures and by calculating the variation of G with T from the Debye-Hückel-Onsager equation. TMean was found to be up to 20°C higher than the external temperature under typical conditions using active air-cooling and a 74.0-μm-internal diameter (di) fused-silica capillary. A combination of experimentally determined and calculated temperatures enables a complete temperature profile for a fused-silica capillary to be drawn and the thickness of the stationary air layer to be determined. As an example, at P/L = 1.00 Wm-1, the determined radial temperature difference across the electrolyte was 0.14°C; the temperature difference across the fused-silica wall was 0.17°C, across the poly(imide) coating was 0.13°C, and across the stationary air layer was 2.33°C. © 2006 American Chemical Society.

History

Publication title

Analytical Chemistry

Volume

78

Issue

8

Pagination

2684-2693

ISSN

0003-2700

Department/School

School of Natural Sciences

Publisher

American Chemical Society

Place of publication

Washington

Repository Status

  • Restricted

Socio-economic Objectives

Expanding knowledge in the chemical sciences

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC