eCite Digital Repository

Differences in aerosol output and airways responsiveness between the DeVibiss 40 and 45 hand held nebulisers

Citation

Hartley-Sharpe, CJ and Booth, H and Johns, DP and Walters, EH, Differences in aerosol output and airways responsiveness between the DeVibiss 40 and 45 hand held nebulisers, Thorax, 50 pp. 635-638. ISSN 0040-6376 (1995) [Refereed Article]

DOI: doi:10.1136/thx.50.6.635

Abstract

Background - The DeVilbiss 40 glass hand held nebulisers have been widely used for airways responsiveness testing in epidemiological surveys ofasthma. These nebulisers have been superseded in some recent studies by the DeVilbiss 45 plastic hand held nebulisers with the assumption that they are interchangeable. This study compared the aerosol outputs of the DeVilbiss 40 and DeVilbiss 45 nebulisers and investigated whether there was any difference in the in vivo measurements of airways responsiveness when using the two nebuliser types. Methods - The aerosol output ofsix DeVilbiss 40 and six DeVilbiss 45 nebulisers was calculated by weight loss per actuation, the usual method of calibrating nebuliser output, and compared with the true amount of aerosol obtained measured by a fluoride tracer technique. Airways responsiveness was measured twice in 13 asthmatic patients under identical conditions by the Yan protocol using DeVilbiss 40 and 45 nebulisers in random order. Results - Weight loss overestimated the true aerosol output of both types of nebulisers. Weight loss was similar for the DeVilbiss 40 and 45 nebulisers but the true aerosol output of the DeVilbiss 45 was nearly twice that of the DeVilbiss 40 nebuliser. The geometric mean PD20 values with the DeVilbiss 40 nebuliser was a mean 1-7 doubling doses of histamine higher than that obtained with the DeVilbiss 45 nebuliser. Conclusions - The Devilbiss 40 and 45 nebulisers should not be used interchangeably for airways responsiveness testing merely because their outputs based on weight loss are similar. Artefactual differences in the prevalence rates of airways responsiveness could occur in longitudinal studies if a change was inadvertently made from using DeVilbiss 40 to DeVilbiss 45 nebulisers.

Item Details

Item Type:Refereed Article
Research Division:Medical and Health Sciences
Research Group:Cardiorespiratory Medicine and Haematology
Research Field:Respiratory Diseases
Objective Division:Health
Objective Group:Clinical Health (Organs, Diseases and Abnormal Conditions)
Objective Field:Respiratory System and Diseases (incl. Asthma)
Author:Johns, DP (Associate Professor David Johns)
Author:Walters, EH (Professor Haydn Walters)
ID Code:35872
Year Published:1995
Web of Science® Times Cited:7
Deposited By:Medicine (Discipline)
Deposited On:2005-09-12
Last Modified:2005-09-12
Downloads:0

Repository Staff Only: item control page