eCite Digital Repository

Separation of hydrophobic polymer additives by microemulsion electrokinetic chromatography

Citation

Hilder, EF and Klampfl, CW and Buchberger, W and Haddad, PR, Separation of hydrophobic polymer additives by microemulsion electrokinetic chromatography, Journal of Chromatography A, 922, (1-2) pp. 293-302. ISSN 0021-9673 (2001) [Refereed Article]


Preview
PDF
Restricted - Request a copy
175Kb
  

Copyright Statement

The definitive version is available at http://www.sciencedirect.com

Official URL: http://www.sciencedirect.com

DOI: doi:10.1016/S0021-9673(01)00950-5

Abstract

Microemulsion electrokinetic chromatography (MEEKC) has been applied to the separation of some phenolic anti-oxidants [Irganox 1024, Irganox 1035, Irganox 1076, Irganox 1010, Irganox 1330, Irgafos 138, Irganox 168 and 2,6-di-tert.-butyl-4-methylphenol (BHT)]. Due to the extremely hydrophobic nature of these analytes, they could not be separated using standard MEEKC conditions and two alternative approaches were investigated. Using an acidic buffer (phosphate, pH 2.5) to effectively suppress the electroosmotic flow, the addition of 2-propanol to the aqueous phase of the microemulsion buffer to improve partitioning of the analytes, and a negative separation voltage, separation of five of the analytes in under 10 min was possible. The second approach, using a basic buffer (borate, pH 9.2) and a positive separation voltage resulted in complete resolution of all eight analytes. A mixed surfactant system comprising the anionic sodium dodecyl sulfate (SDS) and neutral Brij 35 was used to reduce the overall charge and with it the mobility of the droplets, and hence the separation time. Using an optimised MEEKC buffer consisting of 2.25% (w/w) SDS, 0.75% (w/w) Brij 35, 0.8% (w/w) n-octane, 6.6% (w/w) 1-butanol, 25% (w/w) 2-propanol and 64.6% (w/w) 10 mM borate buffer (pH 9.2) the eight target analytes were baseline separated in under 25 min. For these analytes, MEEKC was found to be superior to micellar electrokinetic chromatography in every respect. Specifically, the solubility of the analytes was better, the selectivity was more favourable, the analysis time was shorter and the separation efficiency was up to 72% higher when using the MEEKC method. Detection limits from 5.4 to 26 μg/ml were obtained and the calibration plot was linear over more than one order of magnitude. The optimised method could be applied to the determination of Irganox 1330 and Irganox 1010 in polypropylene.

Item Details

Item Type:Refereed Article
Keywords: Antioxidants; Surfactants; Microemulsion electrokinetic chromatography; Buffer composition
Research Division:Chemical Sciences
Research Group:Analytical Chemistry
Research Field:Separation Science
Objective Division:Expanding Knowledge
Objective Group:Expanding Knowledge
Objective Field:Expanding Knowledge in the Chemical Sciences
Author:Haddad, PR (Professor Paul Haddad)
ID Code:22199
Year Published:2001
Web of Science® Times Cited:42
Deposited By:Chemistry
Deposited On:2001-08-01
Last Modified:2010-02-08
Downloads:0

Repository Staff Only: item control page