eCite Digital Repository
Diagnostic accuracy of artificial intelligence in Glaucoma screening and clinical practice
Citation
Chaurasia, AK and Greatbatch, CJ and Hewitt, AW, Diagnostic accuracy of artificial intelligence in Glaucoma screening and clinical practice, Journal of Glaucoma, 31, (5) pp. 285-299. ISSN 1536-481X (2022) [Refereed Article]
![]() | PDF Pending copyright assessment - Request a copy 467Kb |
DOI: doi:10.1097/IJG.0000000000002015
Abstract
Purpose: Artificial intelligence (AI) has been shown as a diagnostic tool for glaucoma detection through imaging modalities. However, these tools are yet to be deployed into clinical practice. This meta-analysis determined overall AI performance for glaucoma diagnosis and identified potential factors affecting their implementation.
Methods: We searched databases (Embase, Medline, Web of Science, and Scopus) for studies that developed or investigated the use of AI for glaucoma detection using fundus and optical coherence tomography (OCT) images. A bivariate random-effects model was used to determine the summary estimates for diagnostic outcomes. The Preferred Reporting Items for Systematic Reviews and Meta-Analysis of Diagnostic Test Accuracy (PRISMA-DTA) extension was followed, and the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool was used for bias and applicability assessment.
Results:Seventy-nine articles met inclusion criteria, with a subset of 66 containing adequate data for quantitative analysis. The pooled area under receiver operating characteristic curve across all studies for glaucoma detection was 96.3%, with a sensitivity of 92.0% (95% confidence interval: 89.0-94.0) and specificity of 94.0% (95% confidence interval: 92.0-95.0). The pooled area under receiver operating characteristic curve on fundus and OCT images was 96.2% and 96.0%, respectively. Mixed data set and external data validation had unsatisfactory diagnostic outcomes.
Conclusion: Although AI has the potential to revolutionize glaucoma care, this meta-analysis highlights that before such algorithms can be implemented into clinical care, a number of issues need to be addressed. With substantial heterogeneity across studies, many factors were found to affect the diagnostic performance. We recommend implementing a standard diagnostic protocol for grading, implementing external data validation, and analysis across different ethnicity groups.
Item Details
Item Type: | Refereed Article |
---|---|
Research Division: | Biomedical and Clinical Sciences |
Research Group: | Ophthalmology and optometry |
Research Field: | Optical technology |
Objective Division: | Health |
Objective Group: | Clinical health |
Objective Field: | Treatment of human diseases and conditions |
UTAS Author: | Chaurasia, AK (Mr Abadh Chaurasia) |
UTAS Author: | Greatbatch, CJ (Mr Connor Greatbatch) |
UTAS Author: | Hewitt, AW (Professor Alex Hewitt) |
ID Code: | 155600 |
Year Published: | 2022 |
Deposited By: | Menzies Institute for Medical Research |
Deposited On: | 2023-03-02 |
Last Modified: | 2023-03-02 |
Downloads: | 0 |
Repository Staff Only: item control page