Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure

Citation

Sharman, JE and Tan, I and Stergiou, GS and Lombardi, C and Saladini, F and Butlin, M and Padwal, R and Asayama, K and Avolio, A and Brady, TM and Murray, A and Parati, G, Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure, Journal of Human Hypertension pp. 1-8. ISSN 0950-9240 (2022) [Refereed Article]


Preview
PDF (Published)
1Mb
  

Copyright Statement

2022. The Authors. This article is licensed under a Creative Commons Attribution 4.0 International (CC BY 4.0) License (https://creativecommons.org/licenses/by/4.0/), which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.

DOI: doi:10.1038/s41371-022-00693-x

Abstract

Automated 'oscillometric' blood pressure (BP) measuring devices (BPMDs) were developed in the 1970s to replace manual auscultatory BP measurement by mercury sphygmomanometer. Automated BPMDs that have passed accuracy testing versus a reference auscultatory sphygmomanometer using a scientifically accepted validation protocol are recommended for clinical use globally. Currently, there are many thousands of unique automated BPMDs manufactured by hundreds of companies, with each device using proprietary algorithms to estimate BP and using a method of operation that is largely unchanged since inception. Validated automated BPMDs provide similar BP values to those recorded using manual auscultation albeit with potential sources of error mostly associated with using empirical algorithms to derive BP from waveform pulsations. Much of the work to derive contemporary BP thresholds and treatment targets used to manage cardiovascular disease risk was obtained using automated BPMDs. While there is room for future refinement to improve accuracy for better individual risk stratification, validated BPMDs remain the recommended standard for office and out-of-office BP measurement to be used in hypertension diagnosis and management worldwide.

Item Details

Item Type:Refereed Article
Keywords:blood pressure, hypertension, public health, education, accuracy of blood pressure measurement
Research Division:Biomedical and Clinical Sciences
Research Group:Cardiovascular medicine and haematology
Research Field:Cardiology (incl. cardiovascular diseases)
Objective Division:Health
Objective Group:Clinical health
Objective Field:Diagnosis of human diseases and conditions
UTAS Author:Sharman, JE (Professor James Sharman)
ID Code:153012
Year Published:2022
Deposited By:Menzies Institute for Medical Research
Deposited On:2022-09-01
Last Modified:2023-01-13
Downloads:3 View Download Statistics

Repository Staff Only: item control page