Simulation and optimisation of opened sewage concentration air cycle combined with the heat pump under actual weather conditions

Citation

Zhang, Y and Guo, TS and Wu, WF and Li, CY and Wang, XL, Simulation and optimisation of opened sewage concentration air cycle combined with the heat pump under actual weather conditions, IOP Conference Series: Materials Science and Engineering, 06-08 September, London, pp. 1-11. ISSN 1757-8981 (2021) [Refereed Conference Paper]


Preview
PDF
2Mb
  

Copyright Statement

Content from this work may be used under the terms of theCreative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. Published under licence by IOP Publishing Ltd

DOI: doi:10.1088/1757-899X/1180/1/012060

Abstract

Opened air cycle is a promising sewage concentration technology using heated air as the medium to absorb water from the sewage. Unlike closed cycles, the air flow is directly ejected out of the system after humidification in opened cycles. Operating conditions and the circle's efficiency are highly affected by the weather, such as the time-varying ambient temperature and relative humidity. Since the evaporating temperature relies on the ambient temperature, to restrain its dependence, the evaporator was proposed combined with the ejected air flow in this paper. Such a design could improve the efficiency of the heat pump by increasing its evaporating temperature. Simulation of the newly proposed open sewage concentration cycle was performed to investigate its thermal process and economic efficiency under actual weather conditions. Thermodynamic models of the compressor, heat exchangers and the sewage concentration chamber were established. Climatic conditions at Xi'an, China were referenced as actual weather conditions. Optimisation of the working parameters was performed to achieve higher economic index. The results demonstrated that the average monthly power consumption of the optimized cycle was 0.3508 kWh/kg. Compared with the published data of the closed cycle, the total cost of new opened cycle was nearly one-third lower.

Item Details

Item Type:Refereed Conference Paper
Keywords:heat pump, sewage concentration, open cycle
Research Division:Engineering
Research Group:Mechanical engineering
Research Field:Energy generation, conversion and storage (excl. chemical and electrical)
Objective Division:Energy
Objective Group:Energy storage, distribution and supply
Objective Field:Energy systems and analysis
UTAS Author:Wang, XL (Professor Xiaolin Wang)
ID Code:146948
Year Published:2021
Deposited By:Engineering
Deposited On:2021-10-04
Last Modified:2021-12-13
Downloads:8 View Download Statistics