Abstract

Prefabricated construction is becoming increasingly prevalent, however, it is rarely applied in underground constructions, except for tunnel linings, due to the difficulties that arise in jointing various prefabricated components in underground conditions. To solve the vertical location problem of embedded mechanical couplers during the construction of wall–beam–strut joints for a prefabricated metro station, a new connection using welded steel plates is proposed. In this paper, four full-scale specimens of wall–beam–strut joints connected using welded steel plates and mechanical couplers were experimentally tested under monotonic and low-reversed cyclic loading conditions. The testing results were analysed in terms of the ultimate bearing capacity, failure mode, hysteresis, skeleton curve, stiffness degradation, energy dissipation and strain of the reinforcement bars. Notably, the two kinds of joints had similar ultimate bearing capacities and failure modes, but the crack distributions on the tops of the waler beams were different. For the specimens with the welded steel plate connection, tensile horizontal cracks first appeared on the top surface of the beam, where the welded steel plate was located, and then coalesced gradually; however, this cracking pattern was not observed during the experimental test of the specimens connected with the mechanical couplers. Furthermore, it was determined that the energy dissipation and ductility of the welded steel plate connection were better than those of the mechanical coupler connected joint, because the steel plate could redistribute the internal force in the joint and increase the stiffness. It was concluded that the proposed welded steel plate connection could be more favourable than the mechanical coupler connection in the construction of a prefabricated metro station in Guangzhou. Moreover, the results obtained from these experiments could provide guidelines for the corresponding connections employed in underground-prefabricated structures.

Item Details

Item Type:Refereed Article
Keywords:prefabricated metro station, welded steel plate connection, low-reversed cyclic loading, full-scale test
Research Division:Engineering
Research Group:Civil engineering
Research Field:Civil geotechnical engineering
Objective Division:Expanding Knowledge
Objective Group:Expanding knowledge
Objective Field:Expanding knowledge in engineering