Low cost 235 nm ultra-violet light-emitting diode-based absorbance detector for application in a portable ion chromatography system for nitrite and nitrate monitoring

journal contribution
posted on 2023-05-20, 06:30 authored by Murray, E, Roche, P, Harrington, K, McCaul, M, Moore, B, Morrin, A, Diamond, D, Brett PaullBrett Paull
A low cost, UV absorbance detector incorporating a 235 nm light emitting diode (LED) for portable ion chromatography has been designed and fabricated to achieve rapid, selective detection of nitrite and nitrate in natural waters. The optical cell was fabricated through micromilling and solvent vapour bonding of two layers of poly (methyl methacrylate) (PMMA). The cell was fitted within a 3D printed housing and the LED and photodiode were aligned using 3D printed holders. Isocratic separation and selective detection of nitrite and nitrate was achieved in under 2.5 min using the 235 nm LED based detector and custom electronics. The design of the new detector assembly allowed for effective and sustained operation of the deep UV LED source at a low current (<10 mA), maintaining consistent and low LED temperatures during operation, eliminating the need for a heat sink. The detector cell was produced at a fraction of the cost of commercial optical cells and demonstrated very low stray light (0.01%). For retention time and peak area repeatability, RSD values ranged from 0.75 to 1.10 % and 3.06–4.19 %, respectively. Broad dynamic linear ranges were obtained for nitrite and nitrate, with limits of detection at ppb levels. The analytical performance of the IC set up with optical cell was compared to that of an ISO-accredited IC through the analysis of five various water samples. Relative errors not exceeding 6.86% were obtained for all samples. The detector was also coupled to a low pressure, low cost syringe pump to assess the potential for use within a portable analytical system. RSD values for retention time and peak area using this simple configuration were <1.15% and <3.57% respectively, highlighting repeatability values comparable to those in which a commercial HPLC pump was used.

History

Publication title

The Journal of Chromatography A

Volume

1603

Pagination

8-14

ISSN

0021-9673

Department/School

College Office - College of Sciences and Engineering

Publisher

Elsevier

Place of publication

Amsterdam, Netherlands

Rights statement

Copyright 2019 Elsevier B.V.

Repository Status

  • Restricted

Socio-economic Objectives

Scientific instruments

Usage metrics

    University Of Tasmania

    Exports

    RefWorks
    BibTeX
    Ref. manager
    Endnote
    DataCite
    NLM
    DC