Loop-mediated isothermal amplification method targeting the TTS1 gene cluster for detection of Burkholderia pseudomallei and diagnosis of melioidosis

Citation

Chantratita, N and Meumann, E and Thanwisai, A and Limmathurotsakul, D and Wuthiekanun, V and Wannapasni, S and Tumapa, S and Day, NPJ and Peacock, SJ, Loop-mediated isothermal amplification method targeting the TTS1 gene cluster for detection of Burkholderia pseudomallei and diagnosis of melioidosis, Journal of Clinical Microbiology, 46, (2) pp. 568-573. ISSN 0095-1137 (2008) [Refereed Article]


Preview
PDF
291Kb
  

Copyright Statement

Copyright 2008

DOI: doi:10.1128/JCM.01817-07

Abstract

Melioidosis is a severe infection caused by Burkholderia pseudomallei. The timely implementation of effective antimicrobial treatment requires rapid diagnosis. Loop-mediated isothermal amplification (LAMP) targeting the TTS1 gene cluster was developed for the detection of B. pseudomallei. LAMP was sensitive and specific for the laboratory detection of this organism. The lower limit of detection was 38 genomic copies per reaction, and LAMP was positive for 10 clinical B. pseudomallei isolates but negative for 5 B. thailandensis and 5 B. mallei isolates. A clinical evaluation was conducted in northeast Thailand to compare LAMP to an established real-time PCR assay targeting the same TTS1 gene cluster. A total of 846 samples were obtained from 383 patients with suspected melioidosis, 77 of whom were subsequently diagnosed with culture-confirmed melioidosis. Of these 77 patients, a positive result was obtained from one or more specimens by PCR in 26 cases (sensitivity, 34%; 95% confidence interval [CI], 23.4 to 45.4%) and by LAMP in 34 cases (sensitivity, 44%; 95% CI, 32.8 to 55.9%) (P = 0.02). All samples from 306 patients that were culture negative for B. pseudomallei were negative by PCR (specificity, 100%; 95% CI, 98.8 to 100%), but 5 of 306 patients (1.6%) were positive by LAMP (specificity, 98.4%; 95% CI, 96.2 to 99.5%) (P = 0.03). The diagnostic accuracies of PCR and LAMP were 86.7% (95% CI, 82.9 to 89.9%) and 87.5% (95% CI, 83.7 to 90.6%), respectively (P = 0.47). Both assays were very insensitive when applied to blood samples; PCR and LAMP were positive for 0 and 1 of 44 positive blood cultures, respectively. The PCR and LAMP assays evaluated here are not sufficiently sensitive to replace culture in our clinical setting.

Item Details

Item Type:Refereed Article
Research Division:Medical and Health Sciences
Research Group:Medical Microbiology
Research Field:Medical Bacteriology
Objective Division:Health
Objective Group:Clinical Health (Organs, Diseases and Abnormal Conditions)
Objective Field:Infectious Diseases
UTAS Author:Meumann, E (Dr Ella Meumann)
ID Code:129360
Year Published:2008
Web of Science® Times Cited:28
Deposited By:Medicine
Deposited On:2018-11-26
Last Modified:2018-12-11
Downloads:12 View Download Statistics

Repository Staff Only: item control page