eCite Digital Repository

Stability of tigecycline in different types of peritoneal dialysis solutions

Citation

Robiyanto, R and Zaidi, STR and Shastri, MD and Castelino, RL and Wanandy, T and Jose, MD and Patel, RP, Stability of tigecycline in different types of peritoneal dialysis solutions, Peritoneal Dialysis International, 36, (4) pp. 410-414. ISSN 0896-8608 (2015) [Refereed Article]

Copyright Statement

Copyright 2015 International Society for Peritoneal Dialysis

DOI: doi:10.3747/pdi.2015.00170

Abstract

Introduction: Intraperitoneal tigecycline is a potential option for the treatment of peritoneal dialysis (PD)-associated peritonitis caused by microorganisms resistant to commonly used antibiotics. However, the stability of tigecycline must be assessed in the PD solution before evaluating its safety and therapeutic efficacy in PD-associated peritonitis. The objective of this study was to investigate the stability of tigecycline in 3 types of PD solutions at different temperatures for various time points.

Methods: A total of 27 PD bags (9 PD bags for each type of PD solution; 1.5% glucose, 7.5% icodextrin, and 1.5% glucose pH neutral) containing 2 μg/mL of tigecycline were prepared and stored at either 4, 25, or 37C. An aliquot was withdrawn immediately before (0 hour) and after pre-defined time points. Each sample was analyzed in duplicate for the concentration of tigecycline using a stability-indicating high-performance liquid chromatography (HPLC) technique. Samples were also assessed for pH, color changes, and evidence of precipitation immediately after preparation and on each day of analysis.

Results: Tigecycline in all 3 types of PD solutions retained more than 90% of its initial concentration for at least 216, 72, and 8 hours at 4, 25, and 37C, respectively. There was no evidence of precipitation at any time under the tested storage conditions. The pH and color of tigecycline admixed PD solutions stored at 4, 25, and 37C remained essentially unchanged for 336, 96, and 48 hours respectively.

Conclusion: The results obtained from the study provide a platform for future clinical studies aiming to determine the safety and therapeutic efficacy of intraperitoneally administered tigecycline for the treatment of PD-associated peritonitis.

Item Details

Item Type:Refereed Article
Keywords:tigecycline, glucose, icodextrin, pH neutral, peritoneal dialysis, stability, high-performance liquid chromatography
Research Division:Medical and Health Sciences
Research Group:Clinical Sciences
Research Field:Nephrology and Urology
Objective Division:Health
Objective Group:Clinical Health (Organs, Diseases and Abnormal Conditions)
Objective Field:Urogenital System and Disorders
Author:Robiyanto, R (Mr Robiyanto Robiyanto)
Author:Zaidi, STR (Dr Tabish Razi Zaidi)
Author:Shastri, MD (Mr Madhur Shastri)
Author:Castelino, RL (Dr Ronald Castelino)
Author:Wanandy, T (Mr Troy Wanandy)
Author:Jose, MD (Professor Matthew Jose)
Author:Patel, RP (Dr Rahul Patel)
ID Code:104164
Year Published:2015
Web of Science® Times Cited:2
Deposited By:Medicine (Discipline)
Deposited On:2015-11-03
Last Modified:2017-11-01
Downloads:0

Repository Staff Only: item control page